Perspectives: Process Puzzler

Get Relief From Valve Popping

Readers suggest ways to address thermal expansion issue.

*THIS MONTH’S PUZZLER* We’re suffering an annoying thermal expansion problem in the ethylene oxide (EO) lines that feed our reactors: pressure relief valves (PRVs) often pop from solar heating, because lines are blocked in, typically for up to ten minutes. (Our design standard assumes horizontal pipe and a maximum ambient temperature of 95°F, which doesn’t occur very often at our Chicago site: solar flux is 38.7 Btu/h-ft2 for the summer solstice.) The PRVs wouldn’t be such a problem but EO can polymerize and cause them to stick open, which is why the covered area under the reactors is Class 1, Division 1, Group B. The EO feed pipe runs at 55 psig at 60°F. The PRVs are set at 145 psig. Barometric pressure is 14.408 psia. The properties of EO at operating conditions are: density, 66.8 lb/ft3; viscosity, 0.302 cP; heat capacity, 0.476 BTU/lb-F; thermal conductivity, 0.0949 BTU/h-ft2-°R; volumetric thermal expansion coefficient, 0.001°F-1; and bulk modulus, 180,000 psi/ft3. Our plant engineer is convinced that two inches of calcium silicate insulation in a stainless steel jacket over our 1½-in. Schedule-80 Type-316 stainless-steel pipe largely will eliminate our PRV reliability problem. What do you think?

Read more

More from this perspective...

Title

Don't Impair Level Measurements

Several factors can prevent two sensors from giving matching readings.

09/21/2010

Process Puzzler: Deal with a Decanter that Can't

Readers recommend ways to save a standing separator.

10/14/2010

Process Puzzler: Root Out Rumbling

Measurements can confirm the cause of the problem in the fiber-glass piping.

11/11/2010

Vanquish Vexing Venting

Try process-control and equipment changes to eliminate hydrogen losses.

12/13/2010

Process Puzzler: Look Beyond The Valve

Other factors can contribute to persistent valve leaks.

01/14/2011

Choose Cleaning Solvent Wisely

Readers raise a variety of issues to consider.

03/17/2011

Foil Future Fires

Readers point to possible causes of a blaze.

04/05/2011

Heat Exchanger Puzzler: Make the Best of a Blunder

Readers suggest ways to get an incorrect exchanger to do the job.

05/04/2011

Process Puzzler: Spike Tank Spikes

Readers suggest how to avoid column feed tank problems.

05/31/2011

Prevent Pump Problems

Readers suggest possible root causes and ways to improve performance.

07/05/2011

Make Models Match

Readers explain how differences in pressure can arise.

08/09/2011

Silo Holds Mysteries

Readers ponder why an old tank failed.

08/23/2011

Neutralization Requires Basic Rethink

Waste disposal system shouldn't be treated as an afterthought.

10/06/2011

Chillers Require Cold-Eyed Review

Readers suggest ways to avoid temperatures swings and trips.

11/09/2011

Foil Coil Destruction

A number of steps may pre-empt problems

12/13/2011

Don't Be Stumped by a Sump

Several steps can help handle gasoline-laden vent gas.

01/12/2012

Fight a Film Fiasco

Readers suggest how to address heat exchanger fouling and inappropriate cleaning.

02/13/2012

Knock Out Polymerization Process Problems

Tackling equipment and compatibility issues is crucial.

03/13/2012

Don't Scoff At the Expert

Readers recommend significant upgrades to a relief system.

03/21/2012

Burst a Bubble

Readers suggest how to preclude ignition-temperature-test failures.

05/08/2012