Perspectives: Process Puzzler

Beat Dryer Difficulties

Readers suggest ways to get a second-hand unit to perform better

THIS MONTH'S PUZZLER
We bought a used parallel (cocurrent) direct rotary dryer to dry beet pulp. The heating medium is oil passed through a furnace. The feed comes in at 82% water by weight and is supposed to leave at 10%. The nameplate capacity of the dryer is 42,500 pounds per hour (pph); the operating rate at present is only 40,000 pph. A 100-hp fan supplies 45,000 standard cubic feet of air, which is heated to 1,560°F. The fan is taxed, although just 70 hp should be required. The pulp is only dried to 15% when we operate the dryer at full capacity, so we're forced to recycle pulp some of the time. The efficiency, i.e., BTUs required per pound of water evaporated, is supposed to be 1,420 but is about 1,600! Can you suggest why we're using so much heat and what we can do to allow us to limp through the next few weeks until a planned shutdown? What is the long-term solution?

INCREASE THE AIR FLOW
You haven't mentioned whether the beet-pulp flow rate is on a dry basis or a wet basis and the lower heating value of oil isn't specified, so I can't say how much oil you require. But you definitely will need more oil than required for evaporating the water because some energy is being lost in the form of hot air and from the insulation. If the dryer's capacity is as given, then there could be two reasons for the problems:

1. Oil flow rate has decreased. You can verify this by looking at the air temperature after the air heater. If air temperature has decreased, it means oil flow is lower. If your oil flow meter shows the normal value, then check this flow meter and increase the air flow.

2. Air flow rate has decreased. If air flow is lower, then the air will be saturated and won't have the capacity to absorb more moisture. You can verify this by measuring the relative humidity at the dryer outlet or measuring the wet bulb temperature. Air humidity should be less than 90%. If this is the case, then try to increase the air flow. If boosting the air flow isn't possible, then raise the air outlet temperature. This will increase your air inlet temperature, so take care that you are not exceeding the mechanical design temperature limit of the equipment.
Manoj Kumar, manager, central technical services
Reliance Industries Limited, Gujarat, India



CHECK FOR TRAMP AIR
One likely cause could be tramp air. It affects the efficiency of not only dryers but also furnaces. One symptom supporting tramp air as the likely cause is the high power draw by the fan. Get an infrared gun or thermal camera and look at the air ducts and the feed trough. Calculate the actual air flow through the blower from its curve and power draw readings. A dryer should be operating with a slight negative pressure to keep hot gases in; you might also use an anemometer to detect air flow from the dryer. Look especially at seals.

Unfortunately, this may not be the only cause. Too bad the dryer is used equipment. Its history might be helpful. Talk to the commissioning engineers to find out what steps they took to evaluate its initial performance. Hopefully, the commissioning involved an accurate operational acceptance test. Next, talk to the engineer who purchased the dryer, the seller and even the original maker. There's no "Carfax" on used process equipment but historical information may be available on such websites as www.eng-tips.com. You also could google the model and application to see if similar problems have been reported. Beyond that, you're pretty much on your own with used equipment.

There are other potential problems. Is the current feed material the same as what's supposed to be running through the dryer? Was this dryer even designed for this feed? If the flights (ridges) inside the dryer drum are not designed for a material, then the wet solid won't be distributed evenly around the circumference. Solids could clump, producing an inconsistent product or requiring additional dryer residence time and, perhaps, a recycle pass through the dryer.

Is the incoming air dry? If moist air is recirculating back into the dryer from a cold spot, condensation could occur.

Are the temperatures for the incoming and exiting air and for the feed and product correct? Could the oil be fouled? Was the oil flushed during commissioning? Is it the correct oil? Was an oil stabilizer added to reduce corrosion or fouling? What is the oil temperature? If the oil temperature isn't right, look at the furnace. Can you sample the oil? If the oil has broken down or there's sludge, then this could be the source of your mass balance problem.

Some short-term solutions may be of use. High-temperature caulk and insulation may seal the air leaks. Increasing the oil temperature may reduce the dryer performance enough to permit operating at a lower-than-nameplate feed rate; this must be done cautiously because sugar could caramelize, i.e., turn into a burnt or melted oxidized residue that can foul screw flights and sensors like resistance temperature detectors. Another concern is that the sugar is cooled downstream and you don't want to overwhelm the coolers. Adding a defouling agent to the oil may improve heat transfer in the furnace and the dryer. Also, consider some changes upstream. Dehumidifying the air used in the dryers may help. Predrying the feed also may make sense, provided this doesn't adversely affect the feed rate into the dryer. The flow should be steady to produce an even flow in the dryer flights.
Dirk Willard, consultant
Wooster, Ohio


JUNE'S PUZZLER
We're having trouble with the vertical thermosiphon reboiler of the debutanizer column of our fluid catalytic cracker (FCC). The heating medium is the fractionation column bottoms, which arrive at the reboiler shell at a nominal 297°F, following cooling from 682°F in a steam-generating kettle reboiler at the discharge of the fractionation bottoms pump. During startup and shutdown, the discharge from the bottoms pump briefly spikes to 700–715°F. Last year, we abandoned in-place a corroded debutanizer kettle reboiler and have had problems ever since with the thermosiphon. We pull its tube bundle every 8–12 weeks to clean the fouling inside the tubes; now, we're having trouble pulling the bundle. The fractionation column bottoms pump, which was upgraded with a larger impeller and motor at the same time the kettle reboiler was abandoned, is seeing a drop in head, running loud and tripping vibration alarms. What's going on here? What can we do to improve the cycle time of the FCC?

Send us your comments, suggestions or solutions for this question by May 13, 2013. We'll include as many of them as possible in the June 2013 issue and all on ChemicalProcessing.com. Send visuals — a sketch is fine. E-mail us at ProcessPuzzler@putman.net or mail to Process Puzzler, Chemical Processing, 555 W. Pierce Road, Suite 301, Itasca, IL 60143. Fax: (630) 467-1120. Please include your name, title, location and company affiliation in the response.

And, of course, if you have a process problem you'd like to pose to our readers, send it along and we'll be pleased to consider it for publication.

More from this perspective...

Title

Process Puzzler: Serve up better column operation

Readers tackle Chemical Processing's process puzzler question and offer tips about how to keep a stripper column from flooding.

12/21/2004

Process Puzzler: Root Out Rumbling

Measurements can confirm the cause of the problem in the fiber-glass piping.

11/11/2010

Process Puzzler: Replace the Tank

A fiberglass vessel isn't appropriate for the intended use.

11/20/2012

Process Puzzler: Put Railcar Loading Back on Track

Readers suggest how to stop serious safety snags.

04/21/2010

Process Puzzler: Preempt Pump Problems

Readers suggest several options to improve reliability

02/01/2013

Process Puzzler: Master a Musty Mess

Readers suggest how to deal with a contamination source.

08/13/2009

Process Puzzler: Make Solid Progress

Readers suggest ways to improve crystallizer controls.

06/16/2010

Process Puzzler: Look Beyond The Valve

Other factors can contribute to persistent valve leaks.

01/14/2011

Process Puzzler: Keep cables in their place

A Chemical Processing reader was looking for a solution to a cable hanger problem. At his plant, a 200-lb. cable bundle supported by cable hangers fell and injured one man. Read what advice our readers had for him and take a look at next months' question.

02/21/2005

Process Puzzler: Keep Incineration Safe

Readers suggest how to deal with a cyanide-containing fuel.

01/25/2010

Process Puzzler: Kayo a Cascade Control Complication

Readers suggest how to properly regulate an exothermic reaction.

04/24/2009

Process Puzzler: Guard Against Gas

Readers suggest the source of a safety stumper.

11/10/2009

Process Puzzler: Fix a Fluid Flow Flaw

Readers suggest solutions for dryer difficulties.

09/15/2009

Process Puzzler: Eliminate Evaporator Effect

Readers solve an evaporation pump problem.

05/21/2009

Process Puzzler: Deal with dryer drizzle

Readers suggest ways to solve a spray interference problem

06/16/2008

Process Puzzler: Deal with a Decanter that Can't

Readers recommend ways to save a standing separator.

10/14/2010

Process Puzzler: Combat Column Contamination

Readers suggest how to tackle a troublesome tower.

12/15/2009

Process Puzzler: Choose a pump wisely

Readers offer tips about how to choose the best pump for slurry service.

05/25/2005

Process Puzzler: Avoid Another Fatal Accident

Readers consider the causes of a deadly fire.

06/19/2009

Process Puzzler Question: Lengthen media life and reduce operating costs in a pressure filter

Our pressure filter suffers from excessive cake build-up. Although some caking is necessary for efficient filtering, it would be desirable to extend the running time. What do you suggest? Also, do you have any ideas on how we can lengthen media life or reduce operating costs?

06/16/2008