Perspectives: Process Puzzler

Get Relief From Valve Popping

Readers suggest ways to address thermal expansion issue.

*THIS MONTH’S PUZZLER* We’re suffering an annoying thermal expansion problem in the ethylene oxide (EO) lines that feed our reactors: pressure relief valves (PRVs) often pop from solar heating, because lines are blocked in, typically for up to ten minutes. (Our design standard assumes horizontal pipe and a maximum ambient temperature of 95°F, which doesn’t occur very often at our Chicago site: solar flux is 38.7 Btu/h-ft2 for the summer solstice.) The PRVs wouldn’t be such a problem but EO can polymerize and cause them to stick open, which is why the covered area under the reactors is Class 1, Division 1, Group B. The EO feed pipe runs at 55 psig at 60°F. The PRVs are set at 145 psig. Barometric pressure is 14.408 psia. The properties of EO at operating conditions are: density, 66.8 lb/ft3; viscosity, 0.302 cP; heat capacity, 0.476 BTU/lb-F; thermal conductivity, 0.0949 BTU/h-ft2-°R; volumetric thermal expansion coefficient, 0.001°F-1; and bulk modulus, 180,000 psi/ft3. Our plant engineer is convinced that two inches of calcium silicate insulation in a stainless steel jacket over our 1½-in. Schedule-80 Type-316 stainless-steel pipe largely will eliminate our PRV reliability problem. What do you think?

Read more

More from this perspective...

Title

Forestall Fermenter Fouling

Readers suggest how to properly clean unit to eliminate scourge of wild yeast .

05/20/2013

Foil Future Fires

Readers point to possible causes of a blaze.

04/05/2011

Foil Coil Destruction

A number of steps may pre-empt problems

12/13/2011

Fight a Film Fiasco

Readers suggest how to address heat exchanger fouling and inappropriate cleaning.

02/13/2012

February's Process Puzzler: Improve a grandfathered unloading station

Readers suggest ways to improve a grandfathered unloading station in this month's Process Puzzler.

01/30/2007

February Process Puzzler: Isolate Electrical Incidents

Readers unravel a wiring riddle.

02/03/2009

Ensure a Satisfactory Steam System

Readers suggest ways to improve steam operations

08/13/2014

Don’t waste your boilers

Chemical Processing's readers offer tips about how to properly isolate a waste heat boiler.

01/02/2006

Don't Scoff At the Expert

Readers recommend significant upgrades to a relief system.

03/21/2012

Don't Impair Level Measurements

Several factors can prevent two sensors from giving matching readings.

09/21/2010

Don't Be Stumped by a Sump

Several steps can help handle gasoline-laden vent gas.

01/12/2012

December Process Puzzler: Debug a weigh feeder

Readers offer ideas for improving reliability of a weigh feeder in Chemical Processing's monthly Process Puzzler feature.

11/29/2006

Cure column hiccups

12/29/2005

Cope With Condenser Constraints

Readers suggest ways to maintain performance on hot days.

12/10/2012

Condensate cripples compressor

Readers offer tips on how to keep a standby compressor ready for service.

01/05/2006

Clear Up a Compressor Conundrum

Readers decipher a compressor surge.

03/23/2009

Choose Cleaning Solvent Wisely

Readers raise a variety of issues to consider.

03/17/2011

Chillers Require Cold-Eyed Review

Readers suggest ways to avoid temperatures swings and trips.

11/09/2011

Burst a Bubble

Readers suggest how to preclude ignition-temperature-test failures.

05/08/2012

Beat Dryer Difficulties

Readers suggest ways to get a second-hand unit to perform better

03/28/2013