Ease Measurement of Column Internal Flow

Opting for a pump instead of gravity to return liquid to a tower often makes sense

By Andrew Sloley, Contributing Editor

Last month, we looked at using a gravity-flow loop to measure liquid flow inside a column (“Get Some Inside Information”). An often-attractive alternative uses a pump to return the total liquid draw taken from the column. The important engineering fundamentals of this system lie in the pump and control logic.

Figure 1 shows two possible configurations for measuring internal liquid flow in a column using a pump. The upper drawing represents the conventional configuration, i.e., a fixed-speed pump with a flow controller; the lower one depicts a setup with the pump controlled by a variable frequency drive (VFD). The conventional configuration may include a low-flow bypass if rates below the lower operating limit of the pump are expected. Most applications will benefit from a more-modern configuration with level controlled by a VFD.

Total frictional losses in most systems will be low. Typically such losses —from the flow instrument, piping and the return liquid distributor inside the tower — account for at least half of the total system loss. The static head loss between the draw point and return point is relatively small. This makes a good application for a VFD on the pump.

A pump should not run dry. So, control of the upstream level is necessary to protect the pump. This requires adding a level controller span on the collector tray; for effective control the tray must provide sufficient level range, which usually results in high liquid inventory inside the tower. The high liquid level on the tray would make even a small gap on a bolted tray leak a large amount of liquid —undermining the accuracy of measurements because the leaking liquid doesn’t go through the flow meter. So, the tray must be fully welded for leak-free operation.

The control configurations shown assume a centrifugal pump, which means discharge pressure and flow rate are closely linked. Use of a positive displacement pump would require different control configurations.

The pumped system has both advantages and disadvantages compared to a gravity-flow system.

Advantages include:
• The distance between the draw and return points isn’t critical.
• Pressure drop across the flow instrument isn’t a major issue.
• As long as sufficient pipe length for flow conditioning is available, there’s more flexibility in picking instrument locations.
• In vacuum systems, the pump supplies pressure for a sampling station (as shown in the bottom drawing in Figure 1).
• The pump also provides pressure drop for closed sampling stations, if needed.

Disadvantages include:
• The system costs more. The installation requires pump(s), foundation(s), more instrumentation and more-complex control.
• Auxiliary equipment, such as strainers, may be needed to protect the return-liquid distributor inside the tower.
• The critical distance H1 remains. It is necessary for providing sufficient net positive suction head to the pump.
•The pump and associated valves create new locations for potential leaks.
• Unit startup may be more difficult. This often is true when the draw is from a tower with trays and a full collector tray isn’t used to ensure liquid flow to the pump.

Different process requirements may favor either the pumped or the gravity-flow system. However, pumped systems tend to work more often. That’s not due to any magic. Rather, because a pump raises costs, everyone pays greater attention to system fundamentals and layout. As a result, more pumped systems get done right. However, keeping track of the fundamentals and making sure they’re applied correctly always should be a concern.


 

ANDREW SLOLEY is a Chemical Processing contributing editor. You can e-mail him at ASloley @putman.net

More from this perspective...

Title

Keep others from making “classic” mistakes

A heat exchanger problem provides a textbook example of design limitations, according to Contributing Editor Andrew Sloley.

04/24/2007

Don’t let parallel pumps cross you up

Small differences with parallel pumps can lead to big difficulties, according to Andrew Sloley in this month's Plant InSites column.

03/28/2007

Make sure you’ve got a good flange match

Standard large-diameter flanges don’t necessarily mate. Andrew Sloley provides insight in this month's Plant Insites column.

03/06/2007

Take the pressure off pressure control

Linkage of other variables can stymie hot vapor bypass schemes, according to Andrew Sloley's Plant InSites column.

02/19/2007

Understand and Control Hot Vapor Bypass

Contributing Editor Andrew Sloley says pressure control technique works well if implemented properly, in this month's Plant InSites column.

01/08/2007

Make jacketing your strong suit

Small details in jacketed-pipe configuration can have a big impact, according to Chemical Processing's Contributing Editor Andrew Sloley.

12/05/2006

Column configuration can cripple performance

The importance of having the inherent capability to meet operating requirements and enable proper instrumentation performance is stressed by Contributing Editor Andrew Sloley.

09/21/2006

Heat integration steps can present control problems

The more energy prices rise, the more heat integration saves. However, heat integration steps can present complex control problems. Slip-ups in putting control systems in place can make operations nearly impossible. That certainly was the case at one unit using heat recovery.

09/13/2006

Spot problems with adsorbents

The longer-than-expected life of an adsorbent points up the need to always assess the consequences of system additions. While sometimes this may involve detailed calculations, simply looking to the laws of physics can eliminate potential headaches.

08/14/2006

Keep a steady eye on measurements

While engineers often strive to keep processes running without too much variation, measurements that don’t change may be a cause for concern not celebration, as one refinery can attest.

06/19/2006

Keep measurements on the level

Changes in liquid densities can throw off readings. Plants commonly rely on differential pressure (DP) cells to measure level. Read this month's Plant InSites for advice on how to solve these level problems.

04/17/2006

Find the real cause of pump gas up

Simply blaming high feed temperature for inadequate suction isn’t enough when diagnosing pump problems. Read this article to get a laundry list of causes for pump gas up.

04/17/2006

Can you trust your sight glasses?

Sight glasses are invaluable for troubleshooting towers and checking instruments. Improper connections can take a toll on accuracy.

02/17/2006

Is achieving design conditions realistic?

Many factors can influence how equipment should be operated.

08/29/2005

Process Engineering: Inspect with your mind, not just your eyes

A thorough inspection of plant equipment following tiny installations can prevent a lot of future problems. Go beyond just checking for compliance with drawings when looking at hardware and physically look at the equipment itself.

03/11/2005

Process Engineering: Poor compressor design puts pressure on pumps

When a poor compressor design put too much pressure on the pumps, a new solution had to be constructed.  Sometimes the ideal solution is just an intricate compromise.

01/18/2005

Save a bundle solving pressure-drop problems

Pressure drop in compressor-suction and interstage coolers often creates problems. In some cases, just a few pounds of extra pressure drop make a revamp unworkable.

11/04/2004

Give gaskets a squeeze

Reevaluate gasket use when operating conditions or maintenance procedures change.

09/16/2004

Sidestep side-draw control surprises

The simplest approach to control side-draw distillation columns uses flow control on the side product. This solution, however, is not ideal for all side-draw control situations.

07/01/2004

Preheater points out the value of cooling off

Lack of attention to detail in conceptual design can hide many sins. Put the problem aside and then ponder it again. A fresh look may lead to an even better solution.

05/12/2004