Steam Systems: Simple Solutions Can Prompt Complex Problems

Steam systems are especially susceptible to developing difficulties

By Andrew Sloley, Contributing Editor

Related Steam Solutions Content
Over time what seems like a simple solution to a problem often evolves into a larger predicament. Accumulated shortcuts metastasize into major difficulties. In complex plants many of these larger problems ultimately appear in utility systems. Steam systems, in particular, often attract simple solutions and then, because of them, suffer serious troubles.

Consider what befell a large site that originally had conventional condensate handling. As plant operations pushed capacity, lots of services had difficulty in keeping the condensate at high enough pressure to return it to the boiler house. So, many steam exchangers dumped condensate to the concrete pads in the units. In winter the condensate froze, turning large areas of the site into skating rinks. Something had to be done — so the plant installed a fourth, low-pressure condensate system.
Figure 1. Too simple a solution -- Low pressure of
this system led to condensate flashing — and
major problems.
Click on image for larger diagram.

Adding a new condensate system doesn’t necessarily create problems. How you add the system may. The plant buried a vessel for condensate collection on the new system (Figure 1). To minimize pressure, the vessel had an atmospheric vent. A submerged pump sent condensate to the boiler house. A large amount of excess capacity was provided to deal with future expansions.

Condensate flashes when depressurized. The amount of flashing as condensate enters the new drum depends upon the upstream pressure of the condensate. To eliminate equipment, most of the plant’s steam heaters used partially flooded bundles to control exchanger duty (“Don’t Let Heater Control Get you Steamed,” www.ChemicalProcessing.com/articles/2004/81.html). One consequence of using condensate level in a partially flooded bundle for duty control is that the exchanger pressure is always at a maximum on the steam side.
Because increasing exchanger duties created further problems with the other condensate systems, more and more condensate sources were routed to the new atmospheric-pressure system (the one with the extra capacity). The combination of partially flooded exchangers and the low pressure of the new system maximized the pressure drop between the normal consumer and the condensate recovery drum. Significant amounts of condensate vaporized.

The condensate vaporization created two problems. First, much of the steam was vented. The same winter conditions that led the dumped condensate to freeze also led the vented steam to freeze out as icicles on surrounding equipment. Over weeks a large area crusted with ice developed. This caused significant safety and operating problems. (Plus the vented steam is a lost opportunity for energy savings.) Second, the volume expansion from the condensate flashing started to create pressure drop and erosion problems in the low pressure condensate lines.

Placing strategically located intermediate flash drums and replacing the buried drum with a properly designed condensate recovery system solved the plant problems. Steam from flashing condensate was recovered close to groups of major steam consumers. This dramatically reduced condensate flashing in the existing plant lines. The recovered steam went to the next lower pressure level. The energy savings alone paid for much of the work required.

Don’t let simple solutions grow over time into unmanageable problems. Keep in mind that eventually systems reach their limits. At that point, make a step change to improve plant operations instead of letting poor situations fester.

More from this perspective...

Title

Distillation Columns: Get Some Inside Information

A gravity-flow loop can enable measuring internal liquid flow in a column

 

Piping Geometry: Grasp Line Layout

Draining, venting, fouling and other considerations affect piping geometry.

 

Centrifugal Pumps: Fight Flow Recirculation

But first understand why the phenomenon occurs in centrifugal pumps.

 

Select the Right Reboiler

Understand the strengths and weaknesses of various options.

 

Choose the Correct Condenser

Consider a variety of factors when selecting a unit.

 

Consider "Pasteurizing" Your Column

A side-draw may cut capital and energy costs for distillation.

 

Do Liquid Injection Right

A variety of factors influence performance.

 

Odd Layout May Make Even More Sense

Unusual tower configuration better copes with control valve failure.

 

Centrifugal Pumps: Avoid Surprises When Cutting Impellers

Predicting resulting centrifugal pump performance demands care

 

Get Your Head Around Velocity Head

Confusion about what the term means can spell trouble.

 

Workplace Training: Do Your Homework

Evaluate a variety of factors before embarking upon continuing education.

 

Consider VFDs for Centrifugal Pumps

Such drives may provide energy savings and avoid operating problems.

 

Effectively Remove Droplets

Various factors affect the choice and operation of liquid/vapor separators.

 

Old Doesn't Mean Outdated

Some equations have stood the test of time.

 

More Exchanger Area Can Pose Pitfalls

This "obvious solution" for heat-transfer problems may not work.

 

Flow: Avoid Splitting Headaches

Ensuring proper control of parallel flow paths demands care.

 

Ponder the Process Design Basis

Deficiencies in the document can undermine the success of a project

 

Find the real cause of pump gas up

Simply blaming high feed temperature for inadequate suction isn’t enough when diagnosing pump problems. Read this article to get a laundry list of causes for pump gas up.

 

Keep a steady eye on measurements

While engineers often strive to keep processes running without too much variation, measurements that don’t change may be a cause for concern not celebration, as one refinery can attest.

 

Keep measurements on the level

Changes in liquid densities can throw off readings. Plants commonly rely on differential pressure (DP) cells to measure level. Read this month's Plant InSites for advice on how to solve these level problems.