Perspectives: Plant InSites

Distillation Guidelines: Draw Some Important Lessons

Measuring liquid level on a column draw tray demands care

By ANDREW SLOLEY, Contributing Editor

One way to measure liquid flow inside a distillation tower is to infer the flow rate from a liquid level. Figure 1 shows a typical installation. A partial side draw takes a product from a sump on a draw tray while the remaining liquid overflows a weir and continues down the tower. The level measured on the draw tray goes to the plant’s advanced control system, which uses the value in calculating the internal liquid flow rate. In this case, the purpose of obtaining the internal liquid rate was to ensure the trays below the liquid draw had sufficient liquid for proper operation. Trays have a mechanical limit on liquid rates. Below that limit, efficiency may drop dramatically. The tray type and geometry as well as the physical properties of the system determine the minimum acceptable liquid rate. The plant found controlling the distillation specifications of the side-product draw extremely difficult. Purity, especially of heavy components, would vary dramatically for the same calculated liquid internal rate. (Sudden spikes in heavy components in the side draw are strong signals that the internal liquid rate is too low.)

Read more

More from this perspective...

Title

How Important is Piping Symmetry?

Designers should consider the impact of unequal flows in branches.

04/05/2010

Improve Your Plant's Prospects

Keep economics and the lifecycle stage of a facility in mind .

03/04/2010

Is Your Vessel Foundation Really Strong Enough?

Certain situations can lead to exceeding design limits.

12/03/2012

Is achieving design conditions realistic?

Many factors can influence how equipment should be operated.

08/29/2005

Keep Bundle Blunders at Bay

Combining air coolers can provide savings but also pose problems.

03/16/2009

Keep a steady eye on measurements

While engineers often strive to keep processes running without too much variation, measurements that don’t change may be a cause for concern not celebration, as one refinery can attest.

06/19/2006

Keep measurements on the level

Changes in liquid densities can throw off readings. Plants commonly rely on differential pressure (DP) cells to measure level. Read this month's Plant InSites for advice on how to solve these level problems.

04/17/2006

Keep others from making “classic” mistakes

A heat exchanger problem provides a textbook example of design limitations, according to Contributing Editor Andrew Sloley.

04/24/2007

Keep parallel pumps in line

Mind the curves when using different size pumps.

02/13/2008

Let the Buyer Beware

Understand common dangers when developing specifications and evaluating bids.

11/21/2011

Make jacketing your strong suit

Small details in jacketed-pipe configuration can have a big impact, according to Chemical Processing's Contributing Editor Andrew Sloley.

12/05/2006

Make sure you’ve got a good flange match

Standard large-diameter flanges don’t necessarily mate. Andrew Sloley provides insight in this month's Plant Insites column.

03/06/2007

More Exchanger Area Can Pose Pitfalls

This "obvious solution" for heat-transfer problems may not work.

02/01/2012

Nix Nozzle Nuisances

Avoid flow problems by considering the impact of inlet losses.

05/20/2009

Odd Layout May Make Even More Sense

Unusual tower configuration better copes with control valve failure.

01/23/2013

Old Doesn't Mean Outdated

Some equations have stood the test of time.

04/04/2012

Pick the Proper Centrifugal Pump

Consider the impact of startup conditions and prospective operating points.

07/11/2011

Piping Geometry: Grasp Line Layout

Draining, venting, fouling and other considerations affect piping geometry.

09/06/2012

Plant InSites: Cast a cold eye on columns

Subcooling can complicate and compromise tower performance

05/23/2008

Plant InSites: Come Up With a Solid Estimate

Use geometry to figure out the amount of material in storage or equipment.

12/14/2009