Think Straight About Orifice Plates
Insufficient flow conditioning often undermines measurement accuracy.
Plants frequently rely on differential pressure created by an obstruction in a line to measure flow. Accuracy depends upon two factors: the correctness of the differential pressure measurement obtained via taps upstream and downstream, and the calculation for turning that measurement into a flow rate.
The obstruction placed in the line most often is an orifice plate — a flat plate with a machined orifice. (For more on orifice plates, see: "Remember the Old Reliable Orifice Plate," for other differential-pressure flow metering options, see: "Look Beyond Orifice Plates.") Orifice plates are cheap and reliable. Moreover, orifice plates manufactured to specific dimensions and tolerances generate known pressure drops for a given flow rate. The International Standards Organization (ISO) has summarized the dimensional criteria; all reputable orifice-plate manufacturers meet these standards.
ISO standards also cover installation requirements. Proper installation plays a crucial role in achieving accurate orifice-plate measurements. The major criteria include a stable flow pattern, a fluid-filled pipe and an unobstructed flow path (no blockages). If these criteria are met, flow meter calculations can be based on the physical dimensions of the system; no in-place measurement or calibration is required.
Let's look in detail at the first requirement, a stable flow pattern. An oft-repeated rule of thumb states that a length of straight-run pipe equal to 10–15 piping diameters creates a sufficiently stable flow pattern. How does this compare to the ISO standards?
The ISO standards include multiple upstream piping configurations — from fully open full-bore valves upstream and downstream to multiple right-angle turns to tee-branch connections. They also detail for multiple values of β — the orifice diameter/pipe diameter, in consistent units — the length of straight-run piping required (Table 1). In general, the lower the β, the shorter the pipe run necessary. During piping design, the final β ratio is unknown. So, many engineering standards attempt to reduce overall cost by specifying a maximum β of 0.55 to 0.63.
The best cases are fully open full-bore valves with a straight run upstream of them, and a single right-angle bend upstream. The required piping runs for a 0.55 β are 13 diameters for the full-bore valves and 16 diameters for the single right-angle bend. Every other configuration is worse — in some cases, much worse. Higher β values increase upstream requirements.
For two 90° bends in series, an orifice with a 0.55 β requires 44 diameters of upstream piping to meet ISO standards. Even with properly installed straightening vanes, this layout needs 22 diameters. A β of 0.84 raises the requirement to 40+ diameters for all types of installations.
What this all means is that if your plant needs maximum accuracy, use lots of pipe run upstream of orifice plates. In some cases, 90 diameters are necessary. Additionally, if you're having flow meter problems, check the installation. I've observed many orifice meters inside process units that don't meet ISO standards. The 10–15-diameters rule only applies to a "best case" — i.e., everything else is done correctly and a low-β orifice plate is installed. Most industrial installations require 20+ diameters. Using straightening vanes can help, but doesn't completely solve the problem. The toughest installations are downstream of flow branches and where multiple elbows in series are at right angles to each other. To paraphrase a quote from pump installation guidelines, the only thing worse than one elbow upstream of a flow orifice is two elbows.
While a plant may start with low-β orifice plates, as hydraulics become tighter it may put in new plates with lower pressure drops (and higher β values). Installing a short run of larger diameter pipe doesn't solve the problem (Figure 1). The upstream expansion creates a flow pattern with unknown effect on the orifice meter.
If the piping configuration doesn't meet ISO standards, accuracy will suffer. For monitoring unit trends, reduced accuracy may be an acceptable tradeoff for a cheaper meter installation. For high and reliable accuracy, always follow the ISO requirements.
ANDREW SLOLEY is a contributing editor to Chemical Processing. You can e-mail him at Asloley@putman.net.
More from this perspective...
| Title | Date |
|---|---|
|
Dont stack the deck against yourself Always consider future expansions before finalizing layouts |
03/14/2008 |
|
Various factors affect the choice and operation of liquid/vapor separators. |
03/19/2013 |
|
Find the Real Maximum Pressure Of Vessels Always consider static head when assessing pressure vessels. |
04/21/2011 |
|
Find the real cause of pump gas up Simply blaming high feed temperature for inadequate suction isnt enough when diagnosing pump problems. Read this article to get a laundry list of causes for pump gas up. |
04/17/2006 |
|
Full Vacuum Rating Isn't an Empty Benefit It often can provide important but underappreciated advantages for vessels |
10/16/2008 |
|
Get Your Head Around Velocity Head Confusion about what the term means can spell trouble. |
05/02/2012 |
|
Reevaluate gasket use when operating conditions or maintenance procedures change. |
09/16/2004 |
|
Heat Exchangers: Is Mist a Must? Water sprays may boost performance of air-fin exchangers. |
01/02/2013 |
|
Heat integration steps can present control problems The more energy prices rise, the more heat integration saves. However, heat integration steps can present complex control problems. Slip-ups in putting control systems in place can make operations nearly impossible. That certainly was the case at one unit using heat recovery. |
09/13/2006 |
|
How Important is Piping Symmetry? Designers should consider the impact of unequal flows in branches. |
04/05/2010 |
|
Improve Your Plant's Prospects Keep economics and the lifecycle stage of a facility in mind . |
03/04/2010 |
|
Is Your Vessel Foundation Really Strong Enough? Certain situations can lead to exceeding design limits. |
12/03/2012 |
|
Is achieving design conditions realistic? Many factors can influence how equipment should be operated. |
08/29/2005 |
|
Combining air coolers can provide savings but also pose problems. |
03/16/2009 |
|
Keep a steady eye on measurements While engineers often strive to keep processes running without too much variation, measurements that dont change may be a cause for concern not celebration, as one refinery can attest. |
06/19/2006 |
|
Keep measurements on the level Changes in liquid densities can throw off readings. Plants commonly rely on differential pressure (DP) cells to measure level. Read this month's Plant InSites for advice on how to solve these level problems. |
04/17/2006 |
|
Keep others from making classic mistakes A heat exchanger problem provides a textbook example of design limitations, according to Contributing Editor Andrew Sloley. |
04/24/2007 |
|
Mind the curves when using different size pumps. |
02/13/2008 |
|
Understand common dangers when developing specifications and evaluating bids. |
11/21/2011 |
|
Make jacketing your strong suit Small details in jacketed-pipe configuration can have a big impact, according to Chemical Processing's Contributing Editor Andrew Sloley. |
12/05/2006 |