Perspectives: Plant InSites

Think Straight About Orifice Plates

Insufficient flow conditioning often undermines measurement accuracy.

By Andrew Sloley, Contributing Editor

Plants frequently rely on differential pressure created by an obstruction in a line to measure flow. Accuracy depends upon two factors: the correctness of the differential pressure measurement obtained via taps upstream and downstream, and the calculation for turning that measurement into a flow rate.

The obstruction placed in the line most often is an orifice plate — a flat plate with a machined orifice. (For more on orifice plates, see: "Remember the Old Reliable Orifice Plate," for other differential-pressure flow metering options, see: "Look Beyond Orifice Plates.") Orifice plates are cheap and reliable. Moreover, orifice plates manufactured to specific dimensions and tolerances generate known pressure drops for a given flow rate. The International Standards Organization (ISO) has summarized the dimensional criteria; all reputable orifice-plate manufacturers meet these standards.

ISO standards also cover installation requirements. Proper installation plays a crucial role in achieving accurate orifice-plate measurements. The major criteria include a stable flow pattern, a fluid-filled pipe and an unobstructed flow path (no blockages). If these criteria are met, flow meter calculations can be based on the physical dimensions of the system; no in-place measurement or calibration is required.

Let's look in detail at the first requirement, a stable flow pattern. An oft-repeated rule of thumb states that a length of straight-run pipe equal to 10–15 piping diameters creates a sufficiently stable flow pattern. How does this compare to the ISO standards?

The ISO standards include multiple upstream piping configurations — from fully open full-bore valves upstream and downstream to multiple right-angle turns to tee-branch connections. They also detail for multiple values of β — the orifice diameter/pipe diameter, in consistent units — the length of straight-run piping required (Table 1). In general, the lower the β, the shorter the pipe run necessary. During piping design, the final β ratio is unknown. So, many engineering standards attempt to reduce overall cost by specifying a maximum β of 0.55 to 0.63.

The best cases are fully open full-bore valves with a straight run upstream of them, and a single right-angle bend upstream. The required piping runs for a 0.55 β are 13 diameters for the full-bore valves and 16 diameters for the single right-angle bend. Every other configuration is worse — in some cases, much worse. Higher β values increase upstream requirements.

For two 90° bends in series, an orifice with a 0.55 β requires 44 diameters of upstream piping to meet ISO standards. Even with properly installed straightening vanes, this layout needs 22 diameters. A β of 0.84 raises the requirement to 40+ diameters for all types of installations.

What this all means is that if your plant needs maximum accuracy, use lots of pipe run upstream of orifice plates. In some cases, 90 diameters are necessary. Additionally, if you're having flow meter problems, check the installation. I've observed many orifice meters inside process units that don't meet ISO standards. The 10–15-diameters rule only applies to a "best case" — i.e., everything else is done correctly and a low-β orifice plate is installed. Most industrial installations require 20+ diameters. Using straightening vanes can help, but doesn't completely solve the problem. The toughest installations are downstream of flow branches and where multiple elbows in series are at right angles to each other. To paraphrase a quote from pump installation guidelines, the only thing worse than one elbow upstream of a flow orifice is two elbows.

While a plant may start with low-β orifice plates, as hydraulics become tighter it may put in new plates with lower pressure drops (and higher β values). Installing a short run of larger diameter pipe doesn't solve the problem (Figure 1). The upstream expansion creates a flow pattern with unknown effect on the orifice meter.

If the piping configuration doesn't meet ISO standards, accuracy will suffer. For monitoring unit trends, reduced accuracy may be an acceptable tradeoff for a cheaper meter installation. For high and reliable accuracy, always follow the ISO requirements.


ANDREW SLOLEY is a contributing editor to Chemical Processing. You can e-mail him at Asloley@putman.net.

More from this perspective...

Title

Pick the Proper Centrifugal Pump

Consider the impact of startup conditions and prospective operating points.

07/11/2011

Don't Calculate Pressure Drops in a Vacuum

Consider flow regime boundaries and the limitations of methods.

06/08/2011

Find the Real Maximum Pressure Of Vessels

Always consider static head when assessing pressure vessels.

04/21/2011

Properly Assess Energy Recovery Projects

Impact on other operations and transfer prices may alter the economics.

03/09/2011

Consider More Than Static Mixers

A number of technologies can handle pipeline mixing.

01/31/2011

Water Heating Raises More Than Temperature

A key tradeoff complicates the choice between steam and hot oil systems.

01/10/2011

Control Challenges Can Pinch Energy Savings

Heat integration can make achieving effective control more difficult.

11/03/2010

Don't Err With Air-Fin Exchangers

Take considerable care when specifying maximum air temperature.

10/04/2010

Watch Out for Two-Phase Flow

Process performance can suffer dramatically when a liquid flashes unexpectedly.

08/30/2010

Rethink Reactor Temperature Control

Cascade strategy offers simplicity and fast response.

07/13/2010

Software: Show Some Skepticism

Calculated results require critical analysis.

06/14/2010

Properly Trigger Standby Pumps

A pressure signal works for many but not all situations.

05/06/2010

How Important is Piping Symmetry?

Designers should consider the impact of unequal flows in branches.

04/05/2010

Improve Your Plant's Prospects

Keep economics and the lifecycle stage of a facility in mind .

03/04/2010

Check What You're Ordering

A mistake on a purchase order can buy trouble.

02/04/2010

Take a Load Off Loading

Some pipelines may benefit from more than "optimum" insulation.

01/11/2010

Plant InSites: Come Up With a Solid Estimate

Use geometry to figure out the amount of material in storage or equipment.

12/14/2009

Assess the Gravity of the Situation

Flow systems without pumps demand particular attention.

11/09/2009

Plant InSites: Don’t Make Problems for Your Plant

Local fabrication may seem attractive but can degrade performance.

10/22/2009

Will You Really Realize Energy Savings?

Heat integration may deliver complications instead of expected benefits.

09/10/2009