Perspectives: Plant InSites

Distillation Guidelines: Draw Some Important Lessons

Measuring liquid level on a column draw tray demands care

By ANDREW SLOLEY, Contributing Editor

One way to measure liquid flow inside a distillation tower is to infer the flow rate from a liquid level. Figure 1 shows a typical installation. A partial side draw takes a product from a sump on a draw tray while the remaining liquid overflows a weir and continues down the tower. The level measured on the draw tray goes to the plant’s advanced control system, which uses the value in calculating the internal liquid flow rate. In this case, the purpose of obtaining the internal liquid rate was to ensure the trays below the liquid draw had sufficient liquid for proper operation. Trays have a mechanical limit on liquid rates. Below that limit, efficiency may drop dramatically. The tray type and geometry as well as the physical properties of the system determine the minimum acceptable liquid rate. The plant found controlling the distillation specifications of the side-product draw extremely difficult. Purity, especially of heavy components, would vary dramatically for the same calculated liquid internal rate. (Sudden spikes in heavy components in the side draw are strong signals that the internal liquid rate is too low.)

Read more

More from this perspective...

Title

Stripper Bares All

Analysis reveals how operating practices compounded design mistakes

11/21/2008

Steam Systems: Simple Solutions Can Prompt Complex Problems

Steam systems are especially susceptible to developing difficulties

12/23/2008

Spot problems with adsorbents

The longer-than-expected life of an adsorbent points up the need to always assess the consequences of system additions. While sometimes this may involve detailed calculations, simply looking to the laws of physics can eliminate potential headaches.

08/14/2006

Software: Show Some Skepticism

Calculated results require critical analysis.

06/14/2010

Sidestep side-draw control surprises

The simplest approach to control side-draw distillation columns uses flow control on the side product. This solution, however, is not ideal for all side-draw control situations.

07/01/2004

Shell-and-Tube Heat Exchanger

Allocating fluids in a tubular exchanger demands care.

10/23/2013

Select the Right Reboiler

Understand the strengths and weaknesses of various options.

06/04/2012

Save a bundle solving pressure-drop problems

Pressure drop in compressor-suction and interstage coolers often creates problems. In some cases, just a few pounds of extra pressure drop make a revamp unworkable.

11/04/2004

Right Vacuum Control Choice Takes the Pressure Off

Choosing the proper recycle stream for regulation is crucial

08/07/2008

Rethink Reactor Temperature Control

Cascade strategy offers simplicity and fast response.

07/13/2010

Reliability and Maintenance: Don’t Slight Strainers

These simple but often essential devices deserve adequate attention

05/08/2014

Put V-cone Meters on Your Short List

06/10/2013

Pumps: Handle More Flow

Success often depends upon lowering head losses or raising pump pressure

11/04/2014

Properly protect centrifugal pumps

Consider various factors when selecting how to guard against low flow, Andrew Sloley says in this month's Plant Insites column.

07/11/2007

Properly Trigger Standby Pumps

A pressure signal works for many but not all situations.

05/06/2010

Properly Position Interlock Valves

The obvious location may not be the most cost effective

10/16/2012

Properly Assess Energy Recovery Projects

Impact on other operations and transfer prices may alter the economics.

03/09/2011

Process Engineering: Poor compressor design puts pressure on pumps

When a poor compressor design put too much pressure on the pumps, a new solution had to be constructed.  Sometimes the ideal solution is just an intricate compromise.

01/18/2005

Process Engineering: Inspect with your mind, not just your eyes

A thorough inspection of plant equipment following tiny installations can prevent a lot of future problems. Go beyond just checking for compliance with drawings when looking at hardware and physically look at the equipment itself.

03/11/2005

Preheater points out the value of cooling off

Lack of attention to detail in conceptual design can hide many sins. Put the problem aside and then ponder it again. A fresh look may lead to an even better solution.

05/12/2004