Perspectives: Plant InSites

Distillation Columns: Get Some Inside Information

A gravity-flow loop can enable measuring internal liquid flow in a column

By Andrew Sloley

Throughput or fractionation performance in specific systems may vary dramatically depending upon how precisely the internal liquid rate can be controlled close to its limit. Four basic methods can determine the liquid rate within a column:

• calculating heat and material balances using heat input, heat output and external stream rates and properties;
• taking a total draw and then returning liquid through a metered pumped-flow loop;
• taking a total draw and then returning liquid through a metered gravity-flow loop; and
• measuring a column liquid level to infer flow.

Each of these has pros and cons; several or all four might work for a given system. Physical layout and data precision impose particular requirements for each option. Specific systems tend to favor one option or another. Getting the details right counts.

Here, let’s specifically look at taking a total draw and then returning the liquid through a metered gravity-flow loop.

Figure 1 is a partial elevation sketch of a 42-in.-diameter distillation tower. Feed enters the tower between Bed 2 and Bed 3. Beneath Bed 2, a collector tray takes liquid out as a total draw. A gravity-fed loop is used to measure the flow rate of liquid from that collector tray.

I first applied this configuration nearly 25 years ago in a specialty lubricants distillation unit as part of a larger revamp. Discussing that job after the fact, another senior engineer emphatically stated that this type of flow measurement system never could work. He had seen many attempts but none had succeeded. This surprised me because the client was very pleased with its performance. So, we sat down together to review what was built.

Figure 1 highlights seven key features:

1. Collector tray. This serves to gather the liquid. For a packed tower, it’s a default choice. Most applications of this configuration will have a low liquid rate. (A future column will cover the “why.”) Therefore, the tray must be fully welded. A collector tray is a good idea even in a tower with trays. However, with the correct modifications, a special tray configuration may suffice.

2. Nozzle sized for self-vented flow. Vapor bubbles entrained in the liquid reduce system capacity and give incorrect flow-meter readings. Self-vented nozzles have a low enough liquid velocity that vapor can escape and return to the tower. (See: “Assess the Gravity of the Situation.")

3. Sufficient static head. H1 is the minimum distance required to generate enough static head for pressure drop to drive flow through the system. This sets the minimum distance between the draw nozzle and return nozzle elevations. Pipe diameter often is reduced downstream of the self-venting nozzle to cut costs. In that case, H1 must be based on the elevation of the pipe diameter reduction, as shown in Figure 1. In an effort to minimize this height, high-β-value orifice plates often are used to decrease pressure drop.

4. Adequate upstream pipe run. H2 is the minimum upstream pipe run to get well-conditioned flow needed for accurate metering. With orifice flow meters, the higher the β value, the longer the pipe run required. (See: “Think Straight about Orifice Plates.”)

5. Flow instrument in liquid-filled location. The meter can be installed in either a vertical (as shown) or horizontal position. In all cases, the piping configuration must ensure the line is filled with liquid.

6. Long-enough downstream pipe run. H3 is the minimum downstream pipe run necessary for well-conditioned flow for meter accuracy.

7. Suitable distance between the return and lowest-pressure points. H4 is the minimum interval from the return elevation to the lowest-pressure point (vena contracta) to prevent vaporization downstream of the orifice plate. The vena contracta occurs some distance after the orifice plate. Most times, it’s close enough that the orifice plate location can be used to set elevations. Nevertheless, engineers with a good grasp of fundamentals never forget the difference. Avoiding vaporization is important to getting accurate flow measurements. Either H3 or H4 may set the minimum distance from the flow meter to the return nozzle.

One extra point not shown — insulation — is important. In hot systems, a little heat loss makes H4 less likely to set the system. In cold systems, heat gain easily may make H4 dominant. More insulation helps. Vaporization in the system also dramatically may boost pressure drop, increasing H1 as well.

These points apply equally to both packed and trayed towers.

Going back to the discussion with my colleague: After reviewing the system, he asked: “Just how tall was this loop?” The final system with its vertically mounted meter was nearly 30-ft high. Gravity-feed flow-measurement systems require ample height. A horizontal mounting may make H2 and H3 unimportant but H1 and H4 never go away.


ANDREW SLOLEY is a Chemical Processing contributing editor. You can email him at ASloley@putman.net

More from this perspective...

Title

Water Heating Raises More Than Temperature

A key tradeoff complicates the choice between steam and hot oil systems.

01/10/2011

Control Challenges Can Pinch Energy Savings

Heat integration can make achieving effective control more difficult.

11/03/2010

Don't Err With Air-Fin Exchangers

Take considerable care when specifying maximum air temperature.

10/04/2010

Watch Out for Two-Phase Flow

Process performance can suffer dramatically when a liquid flashes unexpectedly.

08/30/2010

Rethink Reactor Temperature Control

Cascade strategy offers simplicity and fast response.

07/13/2010

Software: Show Some Skepticism

Calculated results require critical analysis.

06/14/2010

Properly Trigger Standby Pumps

A pressure signal works for many but not all situations.

05/06/2010

How Important is Piping Symmetry?

Designers should consider the impact of unequal flows in branches.

04/05/2010

Improve Your Plant's Prospects

Keep economics and the lifecycle stage of a facility in mind .

03/04/2010

Check What You're Ordering

A mistake on a purchase order can buy trouble.

02/04/2010

Take a Load Off Loading

Some pipelines may benefit from more than "optimum" insulation.

01/11/2010

Plant InSites: Come Up With a Solid Estimate

Use geometry to figure out the amount of material in storage or equipment.

12/14/2009

Assess the Gravity of the Situation

Flow systems without pumps demand particular attention.

11/09/2009

Plant InSites: Don’t Make Problems for Your Plant

Local fabrication may seem attractive but can degrade performance.

10/22/2009

Will You Really Realize Energy Savings?

Heat integration may deliver complications instead of expected benefits.

09/10/2009

Cut Pump Speed to Cut Problems

Lower rpm can translate into higher reliability.

08/10/2009

View Data from a Different Perspective

Re-plotting by flipping the parametric lines can provide important insights.

07/23/2009

Utility Systems: Don't Rely on Pot Luck

Paying attention to the condensate system can keep you out of hot water.

06/16/2009

Nix Nozzle Nuisances

Avoid flow problems by considering the impact of inlet losses.

05/20/2009

Keep Bundle Blunders at Bay

Combining air coolers can provide savings but also pose problems.

03/16/2009