Perspectives: Plant InSites

Distillation Guidelines: Draw Some Important Lessons

Measuring liquid level on a column draw tray demands care

By ANDREW SLOLEY, Contributing Editor

One way to measure liquid flow inside a distillation tower is to infer the flow rate from a liquid level. Figure 1 shows a typical installation. A partial side draw takes a product from a sump on a draw tray while the remaining liquid overflows a weir and continues down the tower. The level measured on the draw tray goes to the plant’s advanced control system, which uses the value in calculating the internal liquid flow rate. In this case, the purpose of obtaining the internal liquid rate was to ensure the trays below the liquid draw had sufficient liquid for proper operation. Trays have a mechanical limit on liquid rates. Below that limit, efficiency may drop dramatically. The tray type and geometry as well as the physical properties of the system determine the minimum acceptable liquid rate. The plant found controlling the distillation specifications of the side-product draw extremely difficult. Purity, especially of heavy components, would vary dramatically for the same calculated liquid internal rate. (Sudden spikes in heavy components in the side draw are strong signals that the internal liquid rate is too low.)

Read more

More from this perspective...

Title

Don't Let Heater Control Get You Steamed

03/03/2004

Tackle Tough Services for Centrifugal Pumps with Care

03/11/2004

Preheater points out the value of cooling off

Lack of attention to detail in conceptual design can hide many sins. Put the problem aside and then ponder it again. A fresh look may lead to an even better solution.

05/12/2004

Sidestep side-draw control surprises

The simplest approach to control side-draw distillation columns uses flow control on the side product. This solution, however, is not ideal for all side-draw control situations.

07/01/2004

Give gaskets a squeeze

Reevaluate gasket use when operating conditions or maintenance procedures change.

09/16/2004

Save a bundle solving pressure-drop problems

Pressure drop in compressor-suction and interstage coolers often creates problems. In some cases, just a few pounds of extra pressure drop make a revamp unworkable.

11/04/2004

Process Engineering: Poor compressor design puts pressure on pumps

When a poor compressor design put too much pressure on the pumps, a new solution had to be constructed.  Sometimes the ideal solution is just an intricate compromise.

01/18/2005

Process Engineering: Inspect with your mind, not just your eyes

A thorough inspection of plant equipment following tiny installations can prevent a lot of future problems. Go beyond just checking for compliance with drawings when looking at hardware and physically look at the equipment itself.

03/11/2005

Is achieving design conditions realistic?

Many factors can influence how equipment should be operated.

08/29/2005

Can you trust your sight glasses?

Sight glasses are invaluable for troubleshooting towers and checking instruments. Improper connections can take a toll on accuracy.

02/17/2006

Keep measurements on the level

Changes in liquid densities can throw off readings. Plants commonly rely on differential pressure (DP) cells to measure level. Read this month's Plant InSites for advice on how to solve these level problems.

04/17/2006

Find the real cause of pump gas up

Simply blaming high feed temperature for inadequate suction isn’t enough when diagnosing pump problems. Read this article to get a laundry list of causes for pump gas up.

04/17/2006

Keep a steady eye on measurements

While engineers often strive to keep processes running without too much variation, measurements that don’t change may be a cause for concern not celebration, as one refinery can attest.

06/19/2006

Spot problems with adsorbents

The longer-than-expected life of an adsorbent points up the need to always assess the consequences of system additions. While sometimes this may involve detailed calculations, simply looking to the laws of physics can eliminate potential headaches.

08/14/2006

Heat integration steps can present control problems

The more energy prices rise, the more heat integration saves. However, heat integration steps can present complex control problems. Slip-ups in putting control systems in place can make operations nearly impossible. That certainly was the case at one unit using heat recovery.

09/13/2006

Column configuration can cripple performance

The importance of having the inherent capability to meet operating requirements and enable proper instrumentation performance is stressed by Contributing Editor Andrew Sloley.

09/21/2006

Make jacketing your strong suit

Small details in jacketed-pipe configuration can have a big impact, according to Chemical Processing's Contributing Editor Andrew Sloley.

12/05/2006

Understand and Control Hot Vapor Bypass

Contributing Editor Andrew Sloley says pressure control technique works well if implemented properly, in this month's Plant InSites column.

01/08/2007

Take the pressure off pressure control

Linkage of other variables can stymie hot vapor bypass schemes, according to Andrew Sloley's Plant InSites column.

02/19/2007

Make sure you’ve got a good flange match

Standard large-diameter flanges don’t necessarily mate. Andrew Sloley provides insight in this month's Plant Insites column.

03/06/2007