Perspectives: Plant InSites
Effectively Remove Droplets
Various factors affect the choice and operation of liquid/vapor separators.
Plants often use separators to remove liquid droplets from vapor streams. To evaluate the gas capacity of these vessels, engineers typically rely on the empirical Souders-Brown correlation:
V = K [(ρL – ρV)/ρV]0.5
where V is the superficial vapor velocity, K is a constant, ρL is the density of the liquid phase and ρV is the density of the vapor phase. The same equation frequently is used to evaluate packing in distillation, stripping and absorption towers. As a concept this makes sense. Tower packing comes into contact with rising vapor and falling liquid. If the liquid can’t fall, the tower will flood. For distillation towers, the limiting value for K often is given as 0.45 for systems requiring low entrainment and up to 0.50 for systems that can tolerate high entrainment. These values are for high-capacity packings that can operate close to the system limit. However, a specific packing may have a much lower capacity.
The Souders-Brown correlation doesn’t account for any effect of separator height. For towers, that isn’t a major issue because most installations have spacings between internal elements of three feet or less.
Separators, however, often have much more vertical space. This allows for higher capacities in a given plot area. With V in ft/sec and density in consistent units, experience-based values of K for separators are:
• 0.167 for 5-ft-high vertical vessels with the stream entering in the middle of the vessel (values for specific services run from 0.12 to 0.24);
• 0.210 for 10-ft-high vertical vessels with entrance in the middle of the vessel (a range of 0.18 to 0.35 for specific services); and
• 0.35 for spherical vessels and vessels with wire-mesh mist eliminators (a variation of 0.22 to 0.39 for specific services).
For horizontal vessels, you can estimate K via:
K = 0.45 (L/10)0.56
where L is the horizontal vessel length in ft. For such vessels, V is calculated based on the open area above the liquid level. This effectively relates the horizontal travel required for the vapor to give enough time for a droplet to settle horizontally.
Vertical separators are best in applications where gas doesn’t contain much liquid. Horizontal separators are more effective for dealing with large liquid volumes. They also better suit three-phase systems if the two liquid phases are being separated at the same time.
The Souders-Brown correlation and K-factor selected imply a minimum droplet size. Here, the situation becomes a bit unclear. Stokes’ Law, Newton’s Law or the Intermediate Law govern droplet settling. Smaller droplets have lower settling velocities; larger droplets have higher ones. Without special internals (e.g., baffles, impingement plates, cyclones or mesh pads), the maximum size of a droplet that will settle depends upon its terminal velocity. If this is less than the velocity of the rising vapor, the droplet will fall out of the vapor. If the terminal velocity exceeds the velocity of the rising vapor, the droplet will ascend with the vapor.
The upper limit for Stokes’ Law is a droplet Reynolds number of 2. Newton’s Law pertains when Reynolds numbers lie in the 500–200,000 range. Between 2 and 500 — the situation for most industrial systems — the Intermediate Law applies. Droplet removal efficiency is a complex function of droplet size, liquid density, vapor density and vapor viscosity. The effective removal limit for vertical separators varies from a droplet size of 40 μ to 170 μ depending upon the system, vapor velocities and liquid load.
Wire-mesh mist eliminators, by providing both inertial and impaction droplet-removal mechanisms, can push limits down into the 3–10-μ range. However, quoted removal efficiencies of 99–99.5% for such droplets often reflect best-case operation. Contamination of the mesh pad with scale, rust or other solids may dramatically reduce this. Corrosion damage to the pad is another major concern.
Mesh pads have a relatively sharp upper limit on vapor velocity. Operation may alter dramatically with as little as 10% change in vapor rate as the pad approaches its upper operating limit.
Finally, mesh pads create liquid/vapor surface area. Much like with packing, this may promote liquid/vapor mass transfer. In fact, mesh pads often serve as the packing in small diameter columns. Liquid composition in the mesh pad may not be as expected. This can lead to fouled pads.
Like all equipment, separators without and with mesh pads have a specific operating envelope for best performance. Running outside that envelope will likely lower efficiencies. Respect their limits and both should work well.
ANDREW SLOLEY, Contributing Editor
Asloley@putman.net
More from this perspective...
| Title | Date |
|---|---|
| 03/03/2004 | |
|
Teaming two solutions can be counterproductive Sometimes things just dont add up as expected. Andrew Sloley discusses how sometimes two solutions aren't always better than one solution. |
06/06/2007 |
|
Dont look at precondensers in a vacuum Consider the impact of the downstream vacuum ejector on precondenser performance, advises Andrew Sloley, in this month's Plant InSites column. |
08/20/2007 |
|
Do some heavy thinking about light loads Cutting steam demand can get you into hot water, advises Contributing Editor Andrew W. Sloley, contributing editor, in this month's Plant InSites column. |
10/01/2007 |
|
Full Vacuum Rating Isn't an Empty Benefit It often can provide important but underappreciated advantages for vessels |
10/16/2008 |
|
Heat integration steps can present control problems The more energy prices rise, the more heat integration saves. However, heat integration steps can present complex control problems. Slip-ups in putting control systems in place can make operations nearly impossible. That certainly was the case at one unit using heat recovery. |
09/13/2006 |
|
The longer-than-expected life of an adsorbent points up the need to always assess the consequences of system additions. While sometimes this may involve detailed calculations, simply looking to the laws of physics can eliminate potential headaches. |
08/14/2006 |
|
Sidestep side-draw control surprises The simplest approach to control side-draw distillation columns uses flow control on the side product. This solution, however, is not ideal for all side-draw control situations. |
07/01/2004 |
|
Is achieving design conditions realistic? Many factors can influence how equipment should be operated. |
08/29/2005 |
|
Can you trust your sight glasses? Sight glasses are invaluable for troubleshooting towers and checking instruments. Improper connections can take a toll on accuracy. |
02/17/2006 |
|
Keep measurements on the level Changes in liquid densities can throw off readings. Plants commonly rely on differential pressure (DP) cells to measure level. Read this month's Plant InSites for advice on how to solve these level problems. |
04/17/2006 |
|
Find the real cause of pump gas up Simply blaming high feed temperature for inadequate suction isnt enough when diagnosing pump problems. Read this article to get a laundry list of causes for pump gas up. |
04/17/2006 |
|
Keep a steady eye on measurements While engineers often strive to keep processes running without too much variation, measurements that dont change may be a cause for concern not celebration, as one refinery can attest. |
06/19/2006 |
|
Column configuration can cripple performance The importance of having the inherent capability to meet operating requirements and enable proper instrumentation performance is stressed by Contributing Editor Andrew Sloley. |
09/21/2006 |
|
Make jacketing your strong suit Small details in jacketed-pipe configuration can have a big impact, according to Chemical Processing's Contributing Editor Andrew Sloley. |
12/05/2006 |
|
Understand and Control Hot Vapor Bypass Contributing Editor Andrew Sloley says pressure control technique works well if implemented properly, in this month's Plant InSites column. |
01/08/2007 |
|
Take the pressure off pressure control Linkage of other variables can stymie hot vapor bypass schemes, according to Andrew Sloley's Plant InSites column. |
02/19/2007 |
|
Make sure youve got a good flange match Standard large-diameter flanges dont necessarily mate. Andrew Sloley provides insight in this month's Plant Insites column. |
03/06/2007 |
|
Dont let parallel pumps cross you up Small differences with parallel pumps can lead to big difficulties, according to Andrew Sloley in this month's Plant InSites column. |
03/28/2007 |
|
Keep others from making classic mistakes A heat exchanger problem provides a textbook example of design limitations, according to Contributing Editor Andrew Sloley. |
04/24/2007 |


