Perspectives: Making it Work
TDI Plant Pares Steam Consumption
Thinking differently about energy management leads to substantial savings.
Covering 1,700 acres along the Cedar Bayou at the Gulf of Mexico and having roughly 1,000 employees, Bayer MaterialScience's Baytown, Texas, plant is the company's largest manufacturing site in North America. The facility, which began operating in 1971, traditionally has been a focal point of the company's global manufacturing strategy.
As part of the Bayer Group's commitment to climate protection, the TDI (toluene diisocyanate) Train team in Baytown, in collaboration with colleagues at the Isocyanates Technology Center (ITC) in Leverkusen, Germany, undertook a major initiative to substantially reduce the train's energy consumption by optimizing the operation of equipment.
The team operates the Baytown units that produce TDI, a key raw material for polyurethane, via a three-step energy-intensive process: 1) converting toluene to di-nitrotoluene (DNT); 2) transforming DNT to toluene diamine (TDA); and 3) producing TDI from TDA. Each step involves exothermic reactions and uses distillation to purify solvents and products.
Most TDI manufacturing units at Baytown were built between 1998 and 2000. Steam supply for these units primarily comes from a high-pressure steam network utilized throughout the plant. Additionally, the TDI units can import or export steam via an intermediate-pressure steam network. While several energy-integration measures originally were built into the train, changes at the site, such as adding or shutting down other units, reduced the efficiency of these measures.
Bayer MaterialScience sees great value in sharing information globally. So, personnel from the ITC and team members from operating units worldwide participate in monthly teleconferences and annual face-to-face meetings to discuss issues related to operations at their respective sites. These discussions generated ideas for several energy-saving projects at Baytown that would:
• reduce overall steam consumption;
• allow use of lower-value steam; and
• enable recovery of waste steam.
THREE-STEP APPROACH
To spur people to think differently about the issues, the team took what we call the Energy Management System approach. It has three steps. The first consists of an energy efficiency check and improvement plan aimed at identifying potential savings, categorizing necessary measures and then implementing them. The second step, referred to as Energy Loss Cascade & Performance Indicators, involves visualizing energy losses, reporting the losses and the reasons for them, and setting targets for improvement. The third step, dubbed Online Monitoring & Daily Energy Protocol, comprises visualizing deviations from full-rate operation, optimizing energy use and creating awareness of the steps taken.
Following this approach, the team first studied individual units to identify potential opportunities for energy efficiency improvements. In doing so, it sought to determine if existing measures were fully utilized. If they weren't, the team determined the root cause and evaluated possible modifications. It also studied whether there were additional uses for reaction heat, and reviewed distillation efficiency and the solvents used with an eye toward seeking more-energy-efficient choices.
Furthermore, the team assessed the interactions between the TDI units and other areas of the plant. This was done to:
• determine energy needs and potential to supply across the entire site (for example, utilize the heat of the reactions);
• compare total volumes of steam sources of all pressures available for potential use in other units; and
• develop means to modify existing steam supplies to meet needs of units.
As part of this effort, the TDI energy officer monitored energy usage daily and made modifications to optimize unit conditions. In addition, for immediate optimization, operators got access to online models that were developed to compare actual to theoretical best usage.
Based on its findings, the team implemented several TDI Train energy improvement projects.
For example, one effort involved using process simulation tools to evaluate different heat-integration configurations, leading to greater energy efficiency.
The team also conducted cooling-tower load studies. The findings led to consolidating two cooling towers into a single operation, providing additional opportunities for increased efficiency.
Another noteworthy project resulted in installation of an additional steam educator on existing equipment. The original educator only could work at high operating rates; the second educator provided the ability to reduce steam usage across the entire operating rate range.
The site saved 243,000 tons of steam between 2008 and 2010 through these modifications. The reduction in natural gas consumption for steam generation equals the demand of 17,000 American households for a year. Furthermore, the site was able to decrease the amount of steam needed from an outside supplier by approximately 20%.
Besides lowering operating costs, the energy savings projects provide the equivalent of reducing CO2 emissions by approximately 47,450 tons per year.
Additionally, the site achieved a 50% reduction of the energy intensity in one of the units.
In recognition of its efforts, the Baytown TDI Train team received the American Chemistry Council's Responsible Care Energy Efficiency Exceptional Merit award.
The ITC continues to investigate and develop energy savings measures that are applicable across many sites/units, and teams worldwide continue to gather best practices from other sites for implementation at Baytown. The site has formed the Baytown plant energy community to monitor changes to the overall energy balance and look for additional opportunities to improve.
Further, the Energy Management System approach will be fully implemented by the end of 2013 in most Bayer MaterialScience energy-intensive production facilities (those accounting for 85% of energy consumption). This should lead to additional opportunities for optimizing operations and costs.
DONALD PFERDEHIRT formerly was TDI production lead, Bayer MaterialScience LLC, Baytown, Texas, and now is TDI train program manager at the Bayer MaterialScience site in Shanghai, China. E-mail him at Donald.Pferdehirt@bayer.com.
More from this perspective...
| Title | Date |
|---|---|
|
AMS benefits chemical plant from start to finish DuPont engineers chose Intelligent Device Manager software from Emerson Process Management to help manage all the data available from their instrumentation. |
04/08/2005 |
|
Process engineering: Wastewater treatment plant goes the distance A mobile reverse osmosis (RO) system from USFilter effectively treated water at an abandoned fertilizer plant. This allowed system effluent to be discharged into Tampa Bay without environmental impact. |
05/17/2005 |
|
Software Drives OEM Toward Efficiency and Energy Savings ABB designed software for its ACS800 drive so Curtis-Toledo could improve the operation of its rotary-screw compressors. The customized software can control the system pressure, air delivery, oil temperature and duty cycle directly from the drive. |
06/23/2005 |
|
Summit greases its gears to serve global marketplace A lubricant manufacturer increases order accuracy and speeds fulfillment by implementing enterprise resource planning software. |
08/25/2005 |
|
Keep heat-transfer-system repairs uneventful A good plan is the key to avoiding risks in the maintenance of systems using high-temperature organic fluids. |
08/26/2005 |
|
Neville Chemical upgrades efficiency and safety A self-cleaning filter not only allowed one company to add efficiency and safety, it also boosted competitiveness. |
01/03/2006 |
|
Oil refinery minimizes manual tank measurements The strategy was to enhance plant profitability, increase throughput capacity, upgrade product yields and improve on-stream reliability. Read here to find out what they accomplished. |
02/10/2006 |
|
ASM Outperforms Traditional Interface Forty percent of operators at a world-scale North American ethylene plant site discovered that problems were solved 40% faster using new operator interface. |
03/14/2006 |
|
BP tackles Texas City failings British Petroleum's tragic March 2005 explosion has been well-documented through the press. Read here to find out how that tragedy spurred the development of a new program addressing management issues at BP. |
04/12/2006 |
|
Low flow injection improves scale-up of catalysts Dow Chemical recently developed a reactive catalyst for use in one of its production facilities. Indications were that this new catalyst could save the company millions of euros once it reached full-scale production. The challenge was transferring the recipe using this new reactive catalyst from the laboratory to the pilot plant and, ultimately, to the production level. |
08/07/2006 |
|
Sasol plant benefits from reliability improvements Sasol Solvents reduced operating costs by more than $2 million dollars at its plants in Sasolburg, South Africa. The efforts earned the facility the 2005 HART Plant of the Year Award. |
09/14/2006 |
|
Implementing an operations management system Things are changing at warp speed. Manufacturing companies are collecting large volumes of data from data systems but improvements are possible only if the data are analyzed and developed into useful business parameters. |
09/29/2006 |
|
Outsourcing innovation development A new development method may allow breaking away from the pack as companies continue to employ outsource facilities that offer flexibility and foster innovation. |
10/31/2006 |
|
pH sensor stands up to tough conditions Design provides improved reliability in a polymer-precursor batch reactor. Sensors must respond quickly and survive a harsh environment. Poor probe reliability can make the difference between a process that makes money and one that doesnt. |
01/08/2007 |
|
The intrinsically safe fieldbus has arrived Fieldbus has proven its merit in bringing projects online more efficiently, allowing better diagnostics, and control, and reducing maintenance costs and inventories. However, it has been limited in intrinsically safe services. At last, technology has come through once again with a solution. The capacity barrier of FISCO has now been significantly surpassed by a novel split architecture design that has already proven itself in the field. |
02/09/2007 |
|
Sample pump eliminates emissions A compact system significantly improves analyzer accuracy. This innovative turnkey solution for analyzer emissions is a solid-state pump with an ultra-sensitive pressure regulator that mixes a compatible gas with the analyzer samples to achieve a constant vent header pressure even during times of plant upset. |
03/20/2007 |
|
Flame Modeling Provides Matchless Results A computer simulation helps solve a refinery combustion problem. Finding ways to limit NOx from fired heaters, especially under stringent environmental regulations, has become a major concern for the petroleum refining industry. Complying with new stricter regulations, a Texas refinery upgraded the burners in one of its large cylindrical furnaces. |
04/13/2007 |
|
Two bulk conveyors prove better than one Engineers at EaglePicher Corp. in Quapak, Okla., faced some unique problems in manufacturing high-purity isotopic chemicals and wound up addressing them via a unique solution. |
07/11/2007 |
|
Plastic towers can offer economic and operational advantages, and now come in modular designs suitable for bigger loads. Converting to a plastic cooling tower can yield substantial savings. |
08/20/2007 |
|
Membrane Boasts Material Benefits As economical separation of contaminants from natural gas becomes increasingly important, simulation eases the design of innovative module to remove carbon dioxide. Membranes offer potential advantages over other methods. |
09/11/2007 |