Perspectives: Energy Saver

Optimize Electrical Systems, Part I

Many facilities can reduce costs by performing simple operations

By Ven V. Venkatesan, Energy Columnist

An electrical system comprises sub-stations with transformers, busways, switchgears, panel boards and actual electricity consumers. The electricity consumers convert the electricity into useful output, such as motion, heat, light, sound or ionizing chemical solutions. Motion conversion systems, commonly referred as motor-driven systems, are the largest electricity consumers. The U.S. industrial sector consumes more than 700 billion kWhs of electricity and spends over $30 billion annually to drive its electrical motors.

Electrical energy cost control starts with the utility contract itself. Because electricity can’t be generated in advance or stored in large quantity, most utility companies offer very low tariffs during off-peak times such as at night when most non-industrial users stop consuming electricity. Hence, process engineers can review their electrical loads and consider shifting some of the load to low-cost, off-peak power, if possible. Plants operating large chillers can take advantage of these off-peak, low-tariff offers by installing thermal storage systems to shift chiller operations to off-peak hours. Large water-storage pumps and batch-operated wastewater treatment plants also are good candidates for shifting to off-peak hours.

Most plants pay a significant portion of their electricity bill as maximum demand charges, calculated based on the peak consumption rate (peak demand) at any 30-minute period in the monthly billing cycle. In many processing plants (especially batch operations), the average electricity demand isn’t even 65% of the peak demand in each billing cycle. It’s possible to reduce peak demand by properly scheduling processing operations. The process engineer, electrical engineer and the operations staff collectively should work out the scheduling. If possible, stagger some electrical loads, especially simultaneous startups (an electrical motor’s startup current typically is six times higher than the normal running current). The current consumption of each electrical load directly impacts the maximum demand of the plant’s electrical system.      

Another component that impacts maximum demand is the power factor. In simple terms, power factor is the multiplier to evaluate the true load from the actual demand. Because AC induction motors are the largest electricity users in most plants, the power factor goes down due to the reactive load and the demand increases, even though the true power consumption is lower. Some utilities even impose a penalty if the recorded power factor is lower than 0.9 in a billing cycle. Because inductance and capacitance in an electrical circuit create reactive loads in the opposite direction, lower power factors caused by induction motors can be corrected by adding capacitor banks. In many plants, reducing maximum demand charges alone can justify the investment to add capacitor banks .

Electrical motors account for a large share of electricity consumption. Motor controls comprise sensors, switches, timers, relays and other devices for automatically operating a motor to a pre-set criterion. For example, a motor that runs a pump must start when the discharge-side pressure falls to a minimum set point and stop the motor when the pressure rises to a maximum set point. A motor control circuit using pressure switches and relays can control this action automatically. This type of motor control is called simple on-off control.

For smaller-size electrical-motor-driven applications, on-off type controls can save considerable electricity use. Similar opportunities exist in plants where multiple pumps maintain the process water or cooling water systems. The on-off control also can optimize electricity use in conveyor belts and bucket elevators by minimizing operation in empty conditions. Pumps at condensate collection tanks, or pumps at any vessel that has a level controller, also save energy and reduce deterioration of pump life with the help of on-off controls. These controls provide similar energy-saving results to occupancy sensors in offices, photocells in outdoor lights and thermostats in electrically heated process furnaces. A variety of devices can be used and motor-control circuits can be made to reduce motor-driven equipment electricity use.  

Electricity-consuming equipment that is of older design, poorly maintained, improperly sized or not optimally controlled, tends to use too much electricity or use it inefficiently. So, it’s worthwhile to look at the operating condition of the motor-driven equipment in addition to the motor’s efficiency. More cost-reduction opportunities in electrical system will be discussed in the next energy column.


ven-head-shot.jpgVEN V. VENKATESAN is Chemical Processing's Energy Columnist. You can e-mail him at vvenkatesan@putman.net

More from this perspective...

Title

Optimize Key Energy Services

Cutting energy costs is a necessity for chemical plants.

01/17/2013

Optimize Your Compressed Air Systems

Five simple steps could improve air compressor efficiency

05/06/2011

Optimize Your Steam System, Part I

A simple four-step approach can improve steam efficiency.

02/02/2011

Optimize Your Steam System, Part II

A simple four-step process can improve steam efficiency.

03/07/2011

Plant-Wide Energy Assessment Boosts Savings

Base-level analysis reveals potential savings of $1.5 million annually.

11/18/2013

Pump Out Energy Loss

Review the total pumping system to lower electricity bills significantly

07/28/2014

Put energy into people issues

It’s time for a little industrial energy waste amnesty, says Christopher Russell, contributing editor, in this month's Energy Saver column.

10/30/2007

Recover Low Level Heat, Part I

This two-part series highlights innovative concepts for recovering such heat

06/03/2011

Recover Low Level Heat, Part II

Additional innovative options exist to recover such heat

07/27/2011

Resolve to trim that excess air

Five excess air heater good practices can lead the way to peak performance.

02/05/2008

Respond Right to Reduced Rates

Maintaining energy efficiency helps keep operating costs in check.

12/08/2009

Save Cold Cash

Here are a few tips to keep your winter energy bills under control.

10/08/2009

Save Energy In Water Systems, Part I

Plants often miss opportunities to more fully use hot water.

10/13/2011

Save Energy in Water Systems, Part II

Recover cold cash from cooling water systems.

11/16/2011

Say farewell to the old energy paradigm

Controlling costs in today’s market requires a different approach, says Christopher Russell, contributing editor, in this month's Energy Saver column.

10/01/2007

Simplify Your Energy Message

Money loss calculators can spur better operator response to wasted energy.

08/04/2009

Some training courses are worth the price

Learn to use energy tools to make your plant more efficient

06/02/2008

Survey results reveal cost reduction strategies

Learn what large companies do to manage their energy costs in this month's Energy Saver column by Contributing Editor Christopher Russell.

08/20/2007

Tackle organizational obstacles

For energy cost control, aptitude plus operational style equals results, advises Contributing Editor Christopher Russell, in this month's Energy Saver column.

08/28/2007

Take a Fresh Look at Your Process Heaters

A simple four-step program can lead to significant savings.

11/30/2010