SOE Solutions Help Users Document When Events Have Occurred

Feb. 9, 2009
GE Fanuc introduces Sequence of Events Recording for PACSystems

GE Fanuc Intelligent Platforms, a unit of GE Enterprise Solutions, announces the availability of its applied solutions Sequence of Events Recording for PACSystems. GE Fanuc’s SOE solutions can capture both the first event and the sequence of events that occur in the system during a shutdown or a trip sequence to help users document when events have occurred. Providing accurate detection, recording and storing of events, as well as leveraging accurate time stamps, these SOE solutions enable users to analyze when change of states occurred in the process and the precise order of occurrence, down to the millisecond.

Available as a downloadable package, GE Fanuc’s SOE offerings are fully documented solutions for the company’s PACSystems RX3i and RX7i controllers. These solutions consist of PACSystems application codes, a Windows application for Proficy Historian or Microsoft SQL data collection, solution instructions and example analysis screens for Proficy Real-Time Information Portal.

Three SOE solutions are currently available:

  • PACSystems RX7i Embedded SOE – Sequence of Event Recording for the PACSystems RX7i utilizing a VME digital event capture board, a time synchronization board and on-board mirrored event buffering — Each change-of-state input can be configured to be time stamped with millisecond accuracy. The time-stamped information is moved in to the SOE module buffer and mirrored buffer and is cyclically transferred to the PACSystem’s SOE buffer. In turn, this information is periodically transferred over ethernet to the historian collector, which immediately stores the SOE data in the Proficy Historian database.

  • PACSystems RX3i Soft SOE – Software-based Sequence of Events Recording for the PACSystems RX3i controller — This configurable solution utilizes standard RX3i input modules with events buffered in the PACSystem’s memory. The RX3i CPU scans the I/O modules every millisecond. All configured SOE points are stored in a SOE buffer, which is periodically transferred over ethernet to the historian collector. The historian collector then immediately stores the SOE data in the Proficy Historian database.

  • PACSystems RX3i ENIU with SOE — Software-based Sequence of Event Recording for the PACSystems RX3i controller remote Ethernet I/O racks utilizing RX3i SOE software technology — The RX3i ENIU scans the I/O modules every millisecond. All configured SOE points are stored in the ENIU SOE buffer. Fast point changes that would normally not be seen by the head controller can now be captured and stored in the ENIU. Each event is annunciated to the head controller in the I/O exchange and frequently transferred over ethernet to the historian collector, which accumulates the data from all of the ENIUs and stories it directly in the Proficy Historian database. This configurable solution supports standard modules and event buffering in the remote racks, including transient event annunciation.