Some details are not clear from the drawing, so some assumptions were made. The horizontal blades (pitched blades) at each level in the drawing represent two blades mounted at a 45 degree angle. The drawing is approximately to scale, so all of the blades are 100 mm wide.

With those dimensional assumptions, Case 1 will require about 22 KW and Case 2 will require about 20 KW.

The answers by this expert are based on the best available interpretation of the information provided. The consequences of the application of this information are the responsibility of the user. If clarification is needed, please submit a further question.