Q: We have a 50 MMKcl/hr fuel oil-fired, natural draft, box-type furnace. It has a convection bank with a super-heater steam coil sandwiched in between process lines. It is also equipped with soot blowers and normally operates once every 24 hours. Suddenly, stack temperature went up and the furnace is firing is very hard. Please let me know how to confirm whether the convection bank is fouled up or not?

A: The condition described can be due to two reasons:

  1. Incomplete combustion
  2. Reduced heat transfer

To check for incomplete combustion, check the stack for O2 and CO emissions. If the problem is not from incomplete combustion, then the problem is due to reduced heat transfer. Reduced heat transfer can be due to fouling either inside or outside the tubes. If the assumption can be made that fouling and has not occurred inside the tubes, it would be safe to assume that fouling has occurred on the outside of the tubes.

Back to Ask the Experts

More content on this topic:

Solutions Centers

The Optimized Plant

The Optimized Plant

Sponsored by Honeywell

Honeywell can help sustain the life of your assets and maximize the operational performance of your plant or mill.

Wastewater analysis should be easy

Wastewater Analysis Center

Sponsored by Hach

Wastewater analysis should be easy. Learn about wastewater analysis solutions including spectrophotometers and chemistries to get accurate results, time after time.

Business Performance

Business Performance

Sponsored by Honeywell

Improve performance and increase profitability with integrated, comprehensive solutions that protect your people, process and assets, while reducing costs and improving productivity.

Marketplace (Sponsored)