Convection bank performance
Q: We have a 50 MMKcl/hr fuel oil-fired, natural draft, box-type furnace. It has a convection bank with a super-heater steam coil sandwiched in between process lines. It is also equipped with soot blowers and normally operates once every 24 hours. Suddenly, stack temperature went up and the furnace is firing is very hard. Please let me know how to confirm whether the convection bank is fouled up or not?
A: The condition described can be due to two reasons:
- Incomplete combustion
- Reduced heat transfer
To check for incomplete combustion, check the stack for O2 and CO emissions. If the problem is not from incomplete combustion, then the problem is due to reduced heat transfer. Reduced heat transfer can be due to fouling either inside or outside the tubes. If the assumption can be made that fouling and has not occurred inside the tubes, it would be safe to assume that fouling has occurred on the outside of the tubes.
Here are more of the latest questions on: Combustion
Can you explain buoyant thermal force?
In flare tips, we know at minimum flow at low velocity and with no wind the flame of the flare tip is almost vertical. If the wind velocity increases the flame goes horizontal.
We need to explain to our client why this happens. We only know this is a phenomenon called buoyant thermal force, but we do not know the background and governing equations of this behavior. Can you explain?
Can you suggest routine checks for a furnace?
We have a Foster-Wheeler-designed furnace for reforming natural gas. The furnace is induced draft and has two chambers. Can you suggest routine checks an operations engineer must do during normal operation?
Is soot-blowing still applicable?
Is soot-blowing still applicable when natural and or fuel gas with <0.05 wt percentage H2S and <0.1 C6+ is being fired? To me this is a waste of money if the frequency is once a day. On other furnaces and boilers the convection sections are being cleaned every five years with the same fired fuel. I need to convince the owners.
What safety requirements are necessary for a fuel switchover on a furnace?
We have a natural draft furnace designed to use the fuels hydrogen, natural gas and LPG. In the event of a fuels changeover while the furnace is on-line, what are all the safety instruments and controls that should be considered to safeguard the equipment and operating personnel?
Is there a formula to calculate how much wood was present prior to burning?
Is there a formula for calculating remaining wood as residue to calculate how much wood was present prior to being burned? And if so, could the formula be used on remaining wood ash residue that has been exposed to the elements for seven months?
Print page