Cyclone blockage

Q: We have been facing continous (unsolved) problems with cyclone blockage in the reactors on our plant. These cyclones regularly get blocked due to the catalyst inside the reactor. Many options have been considered , each with its own disadvantage. Mechanical hammers/other mechanical solutions usually has the disadvantage of short life span due to the corrosive nature of the catalyst. Magnetic solutions are a possibility as long as it does not influence the reaction to the fact that the catalyst must form a fluidised bed. The reactor is also at very high temperatures (350 degrees celcuis). I wish for any advice or best pratices on cyclone blockage prevention.

A: The query was not very specific on the location of the blockage, and the type of blockage (physical compaction, chemical reaction, or condensation agglomeration) was not spelled out.  However, let me offer some direction:
 

  1. If the blockage is in the inlet or around the upper cylinder and made up of physically compacted solids, the velocity may be too high.  FCC units usually have multiple cyclones in series to avoid this problem and still get good particle collection.  Also, the solids may be building on the roof due to the stagnant areas and some of the reactions may be continuing.  I would look back at past operations and see if the velocity has changed.  If the blockage is due to condensed solids or reaction, there may be some unexpected heat losses or gains.
     
  2. If the blockage is near the solids outlet, there may be condensation of gases depending on the reaction (exothermic or endothermic) and how far the cyclone is from the disengagement zone of the fluid bed.  Also, they may have made a change in operations (throughput or volume of gas flow) that makes the gas velocity lower and this will make the inner vortex shorter than normal.  The result is the lack of shear on the surface that keeps the solids flowing and the solids flow in slugs or stay on the surface for long periods of time.  It is like having funnel flow rather than mass flow in a bin.  The potential for this to happen depends on the style of cyclone (long or short cone with a long or short barrel).
     
  3. The dip legs may be too short or too shallow in the fluid bed.  This may allow them to leak and allow gases to come back up into the cyclone.  The reaction that is supposed to take place in the fluid bed may be taking place in the cyclone.  Also, this may give a different selectivity to the reactants.

A step wise approach would be: First look at the velocity and composition changes that can influence the inlet velocity.  Second, It may be necessary to look at composition of the exhaust gases to identify any leakage.  Third, they would need to take a sample of the solids and look at them under a microscope to determine if the particles are agglomerated.  Depending on the composition of the catalyst, they could run a TEM (transmission electron microscope) analysis to see if the points of contact are the same composition or a condensate from the gases.  Finally, look for heat losses that may be changing the velocity and potential for condensation.

Here are more of the latest questions on: Instrumentation and Control

Can you explain a split range controller?
Regarding split range controller:

  1. Is it normal to have a control valve with two different sizes?
  2. Why use a split range controller and where can we it?
  3. My application: I am planning to use at outlet of condenser. The outlet will have condensate liquid and non-condensate vapor. Will it work here?

Can you explain linearity and accuracy of flowmeters?
I am confused on linearity and accuracy of flowmeters such as oval meters. In some references they are mentioned as the same but in some others they are not the same. Should I only rely on linearity for selection for measuring custody transfer or another flowmeter characteristic?

Can you recommend a flowmeter?
We are going to install a flowmeter for lube oil loading as custody transfer. The flowrate may alter between 140-280 CMH (two-speed motor) having viscosity 150cSt at 40C. Simple installation and setting up on the line and reasonable cost as well as pressure drop are preferred. The pump can generate 8barg pressure. What would be the recommended flow measuring type to support the requested service?

Where should I install the control valve on the hot oil line?
I am going to use hot oil for heating a process in a jacketed vessel and I am going to make a control loop for controlling the vessel content. The hot oil enters at the bottom of the jacket and exits from the top. The control elements are RTD, controller, and control valve. My question: Where should I install the control valve on the hot oil line? Is it up stream or down stream of the vessel?

Why is there a discrepancy of solids at sampling points?
Ours is a fertilizer industry and within the premises we transfer phosphoric acid from the phosphoric acid production facility to the fertilizer production facility. The distance of the pipeline might be around 400m but the difference in issue and receipts generally comes out to be 100s of tons per day. Can you tell me what could be the possible problem? Other info required:

  1. Phosphoric acid has around 5% solids
  2. Sampling point in phosphoric acid tank is at the bottom
  3. Sampling point in the fertilizer plant is at a higher level(25 ft) and is preceded by a lot of bends.
Could this be an issue with the sampling points or the data analysis?