Articles

2161-2180 of 2835 < first | | | last >
  • Get full value from partial stroking

    There are two main drivers for partial stroking of valves in safety systems: the desire to extend manual test intervals to as long as possible; and to reduce the amount of redundant hardware required for higher safety integrity levels. Like most things in life, it all boils down to one thing: trying to save money.

    Paul Gruhn, ICS Triplex
    03/20/2007
  • Tips and traps

    Following some partial stroke testing tips can make the process easier. Read on for more tips.

    Paul Gruhn, ICS Triplex
    03/20/2007
  • Sample pump eliminates emissions

    A compact system significantly improves analyzer accuracy. This innovative turnkey solution for analyzer emissions is a solid-state pump with an ultra-sensitive pressure regulator that mixes a compatible gas with the analyzer samples to achieve a constant vent header pressure — even during times of plant upset.

    Kazi Hassa, Parker Hannifin
    03/20/2007
  • Compelling reasons to choose an insertion magnetic flow sensor

    Measuring flow rates and volumes of water and chemicals in the water, wastewater and chemical treatment industries requires the latest, simple to use and cost-effective technology that can keep up with the rigorous demands of the various applications.

    03/14/2007
  • Can you trust your data?

    To make sense of supply chain data requires consolidating the information into a central repository and then using tools or applications to pinpoint errors and inconsistencies. It also includes taking possible corrective actions that enhance overall quality and confidence in the raw information.

    Andrew Nelson, Matrikon Inc.
    03/14/2007
  • Don’t shackle yourself to the wrong platform

    Today, process data are readily available at many levels, from instrumentation to higher-level data historians and OPC servers. Choosing the right platform can be key to successfully implementing robust and maintainable process calculations at your company.

    Dane Overfield, Exele Information Systems
    03/14/2007
  • Make your portable mixer work for you

    Understanding the fundamentals of fluid agitation can help meet the customer’s requirement and the processor’s need for efficiency. While portable mixers have been around for years, they often aren’t used to their full potential. Knowing the basics of mixing and flow patterns can help you get more out of your mixer.

    David Dickey, MixTech, Inc. and Lydia Booth Fenley, Illes Seasonings & Flavors
    03/06/2007
  • Still pondering whither fieldbus?

    In this month's installment of On the Bus, Contributing Editor John Rezabek predicts HART devices will work so well that your career may be over before you can justify the cost to replace them with fieldbus.

    John Rezabek, Contributing Editor
    03/03/2007
  • First the application, then the product

    CONTROL Editor in Chief Walt Boyes defines a range of applications and types of level measurement devices and techniques used for figuring out even the most complex level measurement problems.

    Walt Boyes, Editor in Chief
    03/03/2007
  • NeSSI taxis for takeoff

    Though acceptance and networking hurdles remain, the New Sampling/Sensor Initiative (NeSSI) is starting to emerge in real-world, standardized, modular process control applications.

    Jim Montague, Executive Editor
    03/03/2007
  • The evolution of plant automation

    Understanding the purpose of control and safety systems helps users ensure each is appropriately optimized. The duties of the SIS are to protect the people, environment and assets against unsafe conditions.

    Angela Summers, PhD, PE, founder of SIS-TECH Solutions
    03/03/2007
  • Pressure control optimization

    Floating pressure control means that, at minimum pressure, the heat required at the reboiler is minimized, its capacity is increased, and fouling is reduced.

    Béla Lipták, PE, CONTROL Columnist
    03/03/2007
  • Are companies ready to break the cycle?

    Executives say chemical industry must focus more on employee retention, according to Editor in Chief Mark Rosenzweig, in his monthly column.

    Mark Rosenzweig, editor in chief
    03/01/2007
  • Pressure tests can spur successful start-up

    Push it: if it breaks it probably needed to be replaced, says Dirk Williard, in this month's Field Notes column. Doing so can help improve your processes.

    Dirk Willard, senior editor
    03/01/2007
  • Use a portfolio approach to energy management

    A business plan for industrial energy management is remarkably similar to financial planning, says Christopher Russell in his Energy Saver column.

    Christopher Russell, contributing editor
    03/01/2007
  • Chemicals transport faces worldly issues

    Global classification and labeling system aims to boost safety, Lynn Bergeson says in this month's Compliance Advisor column.

    Lynn Bergeson, regulatory editor
    03/01/2007
  • Remember the basics of maintenance

    Despite the “buzz” about asset management systems don’t forget the “oilers”, advises Mike Spear, in this month's End Point column.

    Mike Spear, editor at large
    03/01/2007
2161-2180 of 2835 < first | | | last >